PLYWOOD & MDF · CHINA

OUR FACTORY · FILM FACED FORMWORK PANELS

Film Faced Shuttering Plywood

The concrete finish you need. The factory supply to make it happen.

Source film faced shuttering plywood for your walls, slabs, columns and precast forms. Choose 12–25mm panels, the working film and core, then let our factory prepare the sheets, cut parts, samples and export packing around your project.

Thickness options
12 / 15 / 18 / 21 / 22 / 25mm
Core choices
Poplar / Eucalyptus / Hardwood / Combi
Factory supply
Sheets / Cut parts / OEM panels

Available to order · 10–15 days production · Container shipping

Make repeat orders easier to compare.

Keep the panel identity, concrete finish reference and site trial record together. We use your selected construction and requirements to prepare the quotation.

OUR RANGE · YOUR SELECTED CONFIGURATION

Film faced shuttering plywood specification

Panel references and requirements for our quotation
Intended useConcrete formwork for walls, slabs, beams, columns, precast moulds and infill parts
Thickness options12, 15, 18, 21, 22 or 25mm; selected for the formwork arrangement
Sheet and component formats2440 × 1220mm full sheets, 1220 × 1220mm panels and 610 × 300mm small components; custom dimensions available
Core optionsPoplar, eucalyptus, hardwood or combi; selected layup and repair requirements
Working face and reverseF/F, F/W or W/W arrangement; identify smooth or textured finish and the concrete-contact side
Film coloursDark Brown Opaque (DBO), black, yellow or red; selected film reference
Film weight and abrasion120g/m²: 400 rotations; 220g/m²: 750 rotations. Taber / EN 438-2 references with the selected film and test conditions
Bond choicesPhenol-formaldehyde (WBP), melamine / urea-melamine-formaldehyde or MR; select for the exposure and required performance
Density range500–700kg/m³ across the range; selected construction used for handling and loading
Thickness tolerance±0.5mm reference, with measurement condition and acceptance locations recorded
Squareness±2mm reference with the measurement method identified; length and width limits set separately
Construction and pressingOne-time or two-time hot pressing; finger-jointed core option identified separately
Edges and factory workSealed factory edges; quote cutting, drilling, treatment of new boundaries, OEM branding and supplied stage
Sample and documentationSelected construction, working-face trial, applicable material data, inspection and packing records
Pack identificationConfiguration, dimensions, count, batch and shipping marks for each order line

Tell us your core, film, bond and panel size. We’ll prepare a quotation covering the construction, edge treatment and dimensional tolerances you need.

CONCRETE FINISH · PANEL CHOICES · FACTORY SUPPLY

Find the shuttering panel that works for your project.

Order film faced shuttering plywood for walls, slabs, beams, columns and precast forms, with the core, film and factory processing selected around your work. We manufacture the panels and can prepare full sheets, cut blanks or machined components for your formwork schedule.

Start with the casting use, finish photograph or existing panel you have. We help compare 12, 15, 18, 21, 22 and 25mm options, arrange a useful sample and prepare the quotation for your quantities and destination.

Buying for an existing system?

Send the frame or component reference and specified thickness. We connect its working face, finished dimensions, holes and treatment with the supply your workshop needs.

Choosing a new configuration?

Compare named core, film and bond options around the same concrete-finish target. Keep the selected sample and component details with the quotation for an easier repeat order.

For a fixed 18mm purchase, see 18mm Concrete Shuttering Plywood. This range page helps you choose across thicknesses and constructions, then plan the trial, inspection and bulk supply.

WALLS · SLABS · COLUMNS · PRECAST · REPLACEMENT INSERTS

Tell us what you are casting.

Exposed concrete walls

Bring the visible finish, joint layout and tie-hole detail into the facing choice. A trial assembly can include the adjacent panel interfaces that affect the result.

Slabs, soffits and beams

List bottom and side pieces by thickness, direction and finished size. We can prepare the corners and joints around the project’s support and loading arrangement.

Columns and closures

Start with the clear concrete dimensions and overlaps. Identify covering and inset pieces so the cutting, working-face direction and edge treatment follow the assembly.

Precast mould liners

Share the repeated outline, seams, attachments and required face. Keep the drawing revision with replacement orders so each liner matches the mould.

Replacement frame inserts

Show the seating surface, outline, holes and desired facing position. Include machining and coating in the supplied stage before fitting the part.

Civil engineering components

For culverts, retaining elements and special profiles, send the component and exposure requirement. We help select the panel and cutting plan for that detail.

Wall, slab and framed concrete formwork arrangements using film-faced panels
Wall, slab and framed formwork arrangements. Share the element, working face and component schedule you need.

A drawing or photo is enough to begin

The panel supplies the concrete-contact surface within the project assembly. We help turn the available reference into the construction and processing to quote, with the project’s support, connection and deflection requirements carried into selection.

For transport floors, sidewalls or platforms, include their wear, surface, load and attachment needs. Compare mesh-pattern plywood and hexagrip plywood when a textured working face is required.

CORE · PRESSING · BOND · WORKING FACES

Get a quotation for the complete panel.

Choose poplar, eucalyptus, hardwood or combi, with the selected veneer arrangement and repair requirements. One-time or two-time hot pressing and finger-jointed options can be considered for the construction you need. We keep the chosen combination with the panel sample and order line.

Core, surface and supply choices for your quotation
Order decisionRecord in the specificationUseful comparison
Core and layupCore reference, construction, veneer repair limits and required properties.Compare the selected construction, not only a species or commercial grade.
Pressing routeThe offered one-time or two-time hot-pressing route, where specified.Keep the process description alongside the resulting panel requirements.
Finger-jointed optionWhether that construction is permitted and the acceptance conditions.Compare the proposed finger-jointed construction with the required core and performance conditions.
Working face and reverseFilm identity, nominal grammage, colour, smooth or textured condition on each side.Keep the concrete-contact face and permitted reverse use explicit.
Bond and documentationRequired bond performance, method and traceable configuration.Compare equivalent evidence and the actual offered panel.
Supplied stageWhole sheet, cut blank or machined component with identified treatment.Compare price for the same completed supply scope.

Waterproof formwork and bond selection

Tell us about wet concrete, outdoor exposure and the applicable project requirement. The range includes phenol-formaldehyde, melamine and urea-melamine-formaldehyde options, with WBP and MR references. We help choose the adhesive and supporting bond information for the selected panel.

Bring the working film and protection of freshly cut edges or holes into the same supply plan. For machined components, specify which treatment the factory completes and which operations your workshop will perform.

Choose both working surfaces

Use F/F, F/W or W/W with a plain-language description of each face: smooth or textured, film reference and intended use. Identify the concrete-contact side and whether the reverse will also work against concrete. Include any logo and appearance requirement on each face.

FILM CHOICES · SURFACE WEAR · CONCRETE RESULTS

Choose the working film around your finish and use.

Select DBO (Dark Brown Opaque), black, yellow or red, or discuss another film colour. Choose the working-face and reverse-film references with the core, bond and handling requirements.

Film-weight and abrasion references
Nominal film weightAbrasion referenceUse alongside your project plan
120g/m²400 rotations · Taber / EN 438-2 reference.Use the 400-rotation abrasion reference with the selected panel and method; plan support span and service conditions for the project.
220g/m²750 rotations · Taber / EN 438-2 reference.Use the 750-rotation abrasion reference with the selected panel and method; compare project output through the working-trial record.

The 400- and 750-rotation values are abrasion references for the stated film choices. Keep the relevant report, method, conditioning, abrasive wheel, load and endpoint together when abrasion is part of the purchase specification.

Compare the selected surface

The film reference and panel construction identify the material being compared. Keep changes to either with the sample so your team can select a repeatable supply.

Review the result on your forms

A working trial shows concrete appearance and the film, edges and fixing areas after use. Those observations help plan care and compare useful output for the project.

For cleaning chemicals, high temperatures or other special exposure, send the substance and operating conditions. Include any fire, termite-treatment or goods-contact requirement so we can discuss the relevant construction and product information.

THICKNESS · FORMATS · FIT · HANDLING

Plan the purchased sheet and finished component.

The range offers 12, 15, 18, 21, 22 and 25mm thicknesses. Choose the nominal thickness and properties around the formwork design, then identify the finished part or sheet dimensions needed.

Sheet formats and one-face purchasing area
FormatNominal one-face areaOrdering point
610 × 300mm0.1830m²Confirm the small finished format and its intended component.
1220 × 1220mm1.4884m²Specify the square panel and any trim or machining allowances.
2440 × 1220mm2.9768m²Identify the long direction and actual finished-part schedule.

The 610 × 300mm format is a small component. Send a different length, such as 610 × 3000mm, as its own size requirement. Custom formats and machining can follow your schedule. Mark the long direction, working face and trim allowance on component drawings.

Finished thickness and frame fit

The range’s thickness tolerance reference is ±0.5mm. At 18mm nominal, that gives 17.5–18.5mm unless a different finished requirement is selected. The extreme pair differs by 1.0mm; use the frame seating and target face plane when defining replacement inserts.

The ±2mm squareness reference has its own measurement method. Schedule length, width, thickness and component tolerances separately, with measurement locations and panel condition recorded for inspection.

Compare handling mass by thickness

For a 2440 × 1220mm sheet, nominal volume is width × length × thickness. The table uses the range’s 500–700kg/m³ density envelope to calculate material mass.

Calculated material envelope for one 2440 × 1220mm sheet
Nominal thicknessNominal panel volumeAt 500–700kg/m³
12mm0.0357216m³17.9–25.0kg
15mm0.0446520m³22.3–31.3kg
18mm0.0535824m³26.8–37.5kg
21mm0.0625128m³31.3–43.8kg
22mm0.0654896m³32.7–45.8kg
25mm0.0744200m³37.2–52.1kg

The selected construction determines the supplied board weight. Add packaging and other supplied components to the pack and loading plan. For a paintable resin overlay, compare Double-sided MDO Plywood with its own surface and use requirements.

CUTTING YIELD · FINISHED OUTLINE · EDGE TREATMENT

Count the parts and the new edges your order creates.

Choose whole-sheet delivery or include factory cutting and edge treatment in the quotation. The following plan places two 1200 × 1200mm blanks in a 2440 × 1220mm sheet, with 10mm outer trim and a 3mm separating kerf.

After trimming, the usable rectangle is 2420 × 1200mm. Along the length, 1200 + 3 + 1200 = 2403mm leaves 17mm. The blanks use the entire trimmed width, so actual dimensions and squareness must fit this layout before cutting.

Two 1200mm square blanks within a trimmed 2440 by 1220mm sheetThe sheet is drawn at 0.2 display units per millimetre. Each 1200mm square is 240 units. A 3mm kerf is 0.6 units. A 10mm outer trim is 2 units on each edge.Blank A1200 × 1200Blank B1200 × 12002440 × 1220mm purchased sheet10mm edge trim · 3mm separating kerf
Two square blanks within the purchased sheet. The outer trim and separating kerf are drawn to scale.
Two separated blanks with all eight newly cut outer edges identifiedThe two squares use the same scale as the source-sheet drawing. Their eight boundaries total 9600mm. Each square has four 1200mm sides.Blank A4.8m of cut edgesBlank B4.8m of cut edgesAfter trimming and separationBrown outlines: edges to include in treatment
Two finished blanks create eight newly cut edges, totalling 9.6m of boundary to include in treatment.
Area and perimeter for the two-blank cutting plan
StageOne-face panel areaOutside perimeter
Purchased 2440 × 1220mm sheet2.9768m²7.32m
Two finished 1200 × 1200mm blanks2.8800m² total9.60m total
Difference from purchased sheet0.0968m² outside the required blanks2.28m additional perimeter

Include all exposed wood in treatment

At a nominal 18mm planning thickness, edge-wall area is perimeter × thickness: 7.32 × 0.018 = 0.13176m² for the purchased sheet, and 9.6 × 0.018 = 0.17280m² for the two blanks.

The perimeter increases by 2.28m, while trimming exposes the full 9.6m around the blanks. Include holes and later notches as well. Coating quantity uses the selected product’s coverage, number of coats and loss allowance alongside this geometry.

Keep the working face and part identity through later drilling or trimming. Label the final dimensions, drawing revision and selected panel configuration. Useful offcuts can be included as identified closure pieces with their actual size and condition.

USEFUL SAMPLES · FIRST-POUR RESULTS · REPEAT ORDERS

Choose a sample that helps you place the order.

Tell us what you need to approve. A panel piece can show the film, core and edges; a finished component can test fit and machining; a working pour can review the concrete surface. We help prepare the sample and relevant detail around that buying decision.

Concrete interiors, buildings and civil engineering structures showing different formwork application needs
Concrete interiors, building work and civil engineering applications. Use your own finish or project detail to guide the panel trial.

Bring the finish reference available

Show the appearance, joints and tie positions important to your project. Include a working face, treated cut edge and representative fixing or frame interface in the trial. Identify the reverse as well when it will be used later.

A working-trial record for the selected shuttering panel
Record groupDetails to retainWhat it connects
Material identitySample or panel ID, batch, core, film on each side, nominal and measured thickness.The tested piece to the offered construction.
AssemblyPart locations, direction, dimensions, joints, frame or support drawing reference.Each concrete area to its contact panel.
Concrete and release agentIdentified products, mix reference and actual preparation record.The result to the process used for that trial.
Trial conditionsDates, relevant site conditions, stripping stage and changes during the work.Comparable observations and any departures.
Concrete resultWide views, detail photographs, viewing conditions and acceptance decision.The visible outcome to the agreed reference.
Panel after useFace, edges, corners, holes, reverse, repairs and next-use decision.The next task to the actual panel condition.

Keep the trial construction and process identifiable. Record changes to the film, core, concrete, release product or stripping stage so the observed result remains useful when selecting a bulk order or comparing another panel.

After stripping, record the concrete appearance and the panel’s working face, edges, holes and reverse. The accepted finish and preparation needed for the next task help your team select continued use and repeat supply.

FINISH PHOTOGRAPHS · PANEL IDENTITY · PRACTICAL FOLLOW-UP

Make a finish review easy to act on.

Send a wide concrete view, a close-up and the corresponding panel face, with the location and panel identity available. We help bring the material, joint and preparation details into the same discussion.

Information to collect when reviewing a concrete finish issue
ObservationCollect alongside the photographKeep the review open to
Line or step at a jointAdjacent panel IDs, measured thicknesses, seating and joint detail.Panel dimensions, interface and assembly condition.
Local surface markMatching working face, film damage or contamination, and release-agent record.The contact surface and the preparation process.
Surface texture differs by areaPanel-use history, film reference and concrete batch or placement location.Material identity and changes during the work.
Issue near an edge or holeCut and treatment record, component drawing and condition before use.The machined boundary and surrounding detail.
Change after a later roundBefore/after panel images, cleaning, repairs and site-process changes.The full sequence rather than the latest photograph alone.

Keep the affected pack or component reference with the photographs and sequence of work. The site team checks any damage relevant to continued use; we support the panel information, treatment or replacement discussion around that decision.

ACCEPTED CONTACT AREA · ACTUAL COSTS · REPEAT VALUE

Compare the output your project can use.

Keep panel identity, concrete-contact area, accepted finish and maintenance together. A full sheet and a recut closure have different working areas; recording the area used makes the purchasing comparison useful across both.

This four-round planning schedule starts with ten 2440 × 1220mm panels at 2.9768m² per face. Later rounds use a subset of the original ten, with full-face contact, no cutouts and no replacement panels.

Planned contact-area record for ten original full-size panels
RoundFull panels usedAccepted full contact areasAccepted contact area
Round 1101029.7680m²
Round 29823.8144m²
Round 38720.8376m²
Round 46617.8608m²
Schedule total33 panel uses31 accepted panel uses92.2808m²

Attempted contact totals 33 × 2.9768 = 98.2344m²; accepted contact totals 31 × 2.9768 = 92.2808m². Dividing accepted area by the 29.7680m² purchased area gives 3.1 equivalent accepted full-area uses within this schedule.

Use your actual order and site costs

Cost per accepted contact area = included panel and operating costs ÷ accepted concrete-contact area. Use your panel invoice, preparation and maintenance records. Agree the same cost scope for each offer, including freight, labour or other project costs when they belong in the comparison.

For a recut component, record its new working area once in the relevant round. Keep completed work and any planned further use separate, with the panel’s condition and repair needs recorded. Those details help us quote matching repeat supply or a different construction around the result you need.

EDGE PROTECTION · CLEANING · STORAGE · REPAIR

Keep the selected working faces ready for the next task.

Protect new cuts and holes

Include compatible treatment for outer edges, bore walls, notches and repairs. Record the supplied stage so factory work and later site machining follow the same protection plan.

Use the selected release procedure

Keep the product, application and concrete process with the trial reference. Prepare the face cleanly and follow the release product and formwork system instructions.

Clean and handle with care

Protect film, corners and fixing areas during movement and stripping. Use tools suited to the working face, inspect afterwards and allow appropriate drying before storage.

Retain the part’s identity

Record repairs and changes of role against the panel or component. A recut closure receives its own dimensions, protected edges and working-area record.

Store panels flat with suitable support and surface protection. Keep unused stock, inspected reusable parts and material awaiting a site decision identifiable. For repeat orders, send the sample, drawing revision or pack reference with the new quantity and delivery need.

BULK ORDERS · MIXED CONFIGURATIONS · OEM · EXPORT PACKING

Turn your selected panel into a clear bulk order.

Stack of smooth brown film-faced plywood sheets with visible panel edges
Smooth brown film-faced panels stacked for supply. Keep core, thickness, working film and quantities identified on each order line.

Plan mixed and phased deliveries

Separate thicknesses, formats, cores and faces into named configurations. Tell us which material is needed first so we can arrange pack groups and shipment quantities around your receiving schedule.

Keep repeat supply consistent

Carry the selected construction, sample, drawing revision and finish reference into the bulk order. Mark permitted alternatives separately when requesting price options.

Order, receipt and first-use checks
CheckCompare withRecord for follow-up
Configuration and countOrder lines, selected construction and packing list.Pack IDs and actual quantity for each specification.
Face and reverseAgreed film, surface arrangement and appearance criteria.Panel ID, side and location of any discrepancy.
Dimensions and squarenessNamed dimensions, tolerances and agreed measurement method.Measurement condition, locations and results.
Edges and machiningDrawing, supplied-stage scope and completed treatment.Untreated or damaged boundaries and affected parts.
Required evidenceSelected properties, test scope and actual panel configuration.Document identity and any mismatch to the order.
Repeat-use baselineAccepted sample, concrete reference and prior trial record.Any change requiring a new comparison or trial.

The quotation can cover full sheets or components, both film faces, protected edges, OEM printing, inspection and export packing. Compare the same supplied stage, dimensions and usable output for each option.

The bulk-order price range is with the order information below. Production is normally 10–15 days, with container shipping and our 180-day after-sales warranty. MOQ, pack groups, freight terms and the delivery schedule follow the selected order.

For OEM artwork, see Custom Logo Film Faced Plywood. Our freight and export-packing service and production and quality information support the shipment and inspection plan.

Send the casting use, finish photograph or panel schedule already available to sales@plywoodsupplier.cn, or start your factory quotation. We will help complete the material and processing details.

PLAN YOUR PANEL ORDER

Choose the panel. Prove the finish. Plan the next delivery.

Bring the finish photo, component or drawing you have. We help match the working face, construction and factory processing, with a useful sample and clear order lines for repeat supply.

Film Faced Shuttering Plywood

Your formwork panel and factory supply

  • Concrete element, finish photo, existing panel or drawing
  • Thickness, core and film choices, sheet or cut-part schedule
  • Quantities, samples, packing and delivery destination
View the product specification

Choose a sample for your project

The panel and concrete finish, checked together

Choose the concrete finish or form detail you want to compare. Keep the selected panel, working face, joint and protected edge with the trial conditions and result.

Review this product’s sample plan

For a quotation, add your quantity, destination and required timing. You can start with the details you already have.

PanelSource · Xuzhou PanelSource Co., Ltd.
https://www.plywoodsupplier.cn/product/film-faced-shuttering-plywood/
sales@plywoodsupplier.cn

SAMPLES & ORDER PLANNING

Plan the first order.

Samples
Standard samples without special work or a logo have no sample charge; delivery is separate. Custom samples are agreed individually.
Order quantity
Our starting guidance is one container for standard sizes and 3,000–10,000 pieces for custom sizes or designs. Tell us your trial quantity.
Production
All products are made to customer order. Production takes 10–15 days; the order confirmation records the start date and production schedule. Sea transit is additional.
Payment
Where a deposit applies, our standard reference is 30% before production, with the balance after inspection and before loading. T/T or L/C terms are agreed for the order.
Shipping
Panel orders ship by container. Share your destination so we can arrange the loading plan and quote the freight separately from production.
After-sales warranty
All products include a 180-day after-sales warranty. Contact our team with the order reference and details of any product concern.

Tell us your quantity, sample needs and target delivery date. We’ll put the price, payment terms and production schedule into your quotation.

PRODUCT-SPECIFIC QUESTIONS

Questions about shuttering plywood orders

How do I choose film faced shuttering plywood for my project?

Start with what you are casting, the concrete finish you want and a panel photo or formwork drawing. Our factory helps select the thickness, core, working film, bond and processing, then prepares a sample and quotation for the supply you need.

Which thicknesses and panel sizes can I order?

Choose 12, 15, 18, 21, 22 or 25mm. Formats include 2440 × 1220mm full sheets, 1220 × 1220mm panels and 610 × 300mm small components. Send custom sizes or the final part schedule for a cutting and supply quotation.

Which core and bond options are available?

Choose poplar, eucalyptus, hardwood or combi with the selected layup and pressing route. Bond references include phenol-formaldehyde WBP, melamine or urea-melamine-formaldehyde, and MR. Share the wetting, use conditions and material requirements so the selected bond suits your application.

What film and face arrangements can I choose?

Film references include Dark Brown Opaque, black, yellow and red, with 120g/m² and 220g/m² options. F/F, F/W and W/W identify face arrangements; write the smooth or textured finish and concrete-contact role for each side into the selection.

How do film abrasion values help with selection?

The film references list 400 rotations for 120g/m² and 750 for 220g/m² with a Taber / EN 438-2 reference. Compare them with the selected film and test conditions. A site trial then connects your concrete finish, release procedure and panel care with useful working output.

What tolerances and weight information should I use?

The range lists ±0.5mm thickness and a separate ±2mm squareness reference with its measurement method. Set length, width and machined-part limits for the order. Density spans 500–700kg/m³; use the selected construction and actual format for handling and loading calculations.

Can you supply cut parts, holes and custom branding?

Yes. Send the part drawing, quantities, working-face direction and any artwork. We can include cutting, drilling, protection of new edges and hole walls, part identification and project packing in the factory quotation.

How should I assess samples and continued reuse?

Retain a sample of the selected construction and a useful casting trial record. Compare the concrete finish, working film, joints, edges and fixing areas after use, with the release and care procedure recorded. Inspect the current panel condition before its next task.

Can you arrange mixed sizes and repeat deliveries?

Yes. Separate configurations by core, thickness, film and finished size, with quantities and pack marks for each line. Keep the selected sample and any changed drawing or artwork revision with the supply schedule for repeat orders.

What are the production, shipping and warranty terms?

Available to order, with production normally 10–15 days and container shipping. Freight terms follow the specific order. Our 180-day after-sales warranty applies. Send your panel schedule, quantities and destination for a factory quotation.

CONTACT OUR FACTORY

Let’s prepare the panels for your next concrete project.

Send the use, finish photo or panel schedule available, with quantity and destination. Our factory team helps complete the construction and processing choices and prepares a clear supply quotation.

  • Application and concrete appearance reference
  • Core, face/reverse film, bond and required evidence
  • Thickness, dimensions, tolerances and quantity per order line
  • Whole sheets or machined parts, edge treatment and OEM details
  • Sample scope, packing, destination port and delivery window

Have a finish photograph, existing panel or drawing? Email it to sales@plywoodsupplier.cn. Start with the details you have; we’ll help you work through the rest.

Send us your panel requirements.

Tell us your panel, dimensions, quantity and destination port.

Request a quote ↗