Choosing structural plywood starts with the building component and its layout. Send a floor, wall, roof or formwork drawing, and we can discuss the panel construction, supplied sizes and processing against your project requirements. We manufacture plywood in our own factory. Bring the designer's grade, exposure and performance schedule into the discussion as the panel choice develops, so the quotation stays connected to the intended assembly.
Structural plywood Roof sheathing plywood Film faced formwork plywood
Start with the panel's job in your building
A floor panel spanning between supports, wall sheathing transferring in-plane forces and a plywood web in an engineered member have different loading and connection requirements. Identify the role on the drawing before comparing thicknesses or prices. A visible wall lining may have no assigned structural function even when it looks like structural sheathing.
Provide the support arrangement, load information and required performance established by the project designer. State whether the panel is a permanent part of the building or a temporary construction component. Formwork, for example, involves its own loading, support and use conditions.
Our building-application guide helps distinguish panel roles within a floor, wall or roof assembly.
Choose a route for permanent construction or formwork
Start with the panel's assigned job, then develop the quotation around its specified construction and use conditions. Roof and wall sheathing, floor panels and concrete formwork need different project information even when suppliers use the same broad construction-plywood description.
Permanent load-bearing construction
Keep the required grade, panel directions, supports and connections beside the proposed configuration. Use the structural plywood document checklist to organise the required product evidence. For a roof deck, follow the roof sheathing exposure brief and roof panel approval checklist for the intended construction and completed assembly.
Concrete formwork and temporary works
Describe the pour, loading, support and fixing arrangement together with the working surface and planned use. Compare the substrate and film face through the film faced plywood sample plan. Retain the temporary-works designer's panel and support requirements in the order; the selected film surface and fit sample do not establish the formwork assembly's capacity.
Connect the selected panel to the project grade
For projects using European specifications, EN 636 covers plywood for structural and non-structural applications under defined exposure conditions. Read the complete product designation and the documents supporting the intended use. Keep the required structural designation visible alongside the panel construction.
EN 13986 addresses characteristics, conformity evaluation and marking for wood-based panels used in construction. Where this framework applies, connect the supplied product to its relevant documentation. A logo reproduced in a brochure is not a substitute for product identity and declared characteristics.
For another destination or specification system, identify the applicable requirements explicitly. Do not translate grades between different systems solely because the names or nominal thicknesses look similar.
Where the project specifies US-rated sheathing, identify the required product standard, grade and span rating as well as the bond classification. APA explains plywood grades, span ratings and bond classifications. A span rating belongs with its panel direction, supports and loading conditions; Exposure 1 or Exterior describes bond durability. Keep the requested system and supporting product evidence with the proposed configuration.

Specify exposure separately from surface finish
Describe the expected service environment and construction-stage exposure. A protected wall cavity, an indoor floor and a permanently exposed component have different moisture conditions. Include any wetting risk, drainage detail and treatment requirement in the project information.
Bond durability and resistance to biological deterioration are separate questions. A durable adhesive does not make the wood immune to decay, while a decorative or film overlay does not protect every cut edge, joint or fastener penetration. The specified construction needs to match the complete exposure detail.
For an overlaid panel, identify both the substrate and the working surface. A surface may be selected for cleanability, appearance or wear without providing the missing structural evidence. Our specialty-plywood guide explains how to separate these requirements.
Request the design data in the required directions
Bending strength and stiffness are separate properties, and plywood can have different values in its principal directions. Also identify any relevant tension, compression, panel shear or planar shear requirement. A single bending number cannot represent every force acting in the component.
EN 12369-2:2025 addresses characteristic values for structural plywood design and specifies limits on the panel constructions within its scope. Its stated route must not be applied automatically to an arbitrary thin sheet or unusual lay-up.
Keep typical test averages, characteristic values and design values distinct. The project design method determines the adjustments and checks needed for the actual use. Our property-data guide explains the measurements behind these terms.
Evaluate thickness with supports and connections
Thickness selection needs the support layout, panel direction and required component response. Increasing thickness can change stiffness, weight and connection geometry at the same time. Check actual finished thickness and tolerances where grooves, clips or adjoining layers depend on fit.
Connections transfer load into and out of the panel. Identify fastener type, location, support material, edge details and any openings on the design drawing. Keep the connection detail with the selected sheet so the project designer can assess the assembled load path.
Our stiffness-selection guide discusses thickness, orientation and support changes. Keep those comparisons connected to the designed assembly rather than assigning a universal load rating to one nominal thickness.
Compare panel options for the same layout
| Item | Information to compare | Mismatch to resolve |
|---|---|---|
| Product identity | Grade, construction and document reference | Same trade name but different substrate |
| Exposure | Intended conditions and bonding evidence | Interior evidence offered for exterior use |
| Mechanical values | Property, direction, units and statistical basis | Typical average compared with a characteristic value |
| Dimensions | Finished size, thickness and tolerances | Nominal thickness used where actual fit matters |
| Assembly | Support, fixing and edge requirements | A different installation assumed in the comparison |
| Additional performance | Relevant fire, emission or treatment documentation | A surface label used to imply an unrelated classification |
Do not rank hardwood above softwood, or softwood above hardwood, as an unrestricted strength rule. Compare the specified products and their applicable evidence. A higher price or smoother face does not resolve a missing design property.
Connect the approved configuration to the order
Start the quotation with the specified product and design revision, then identify the construction, thickness and panel direction that must remain unchanged. Keep the required values, units and supporting document references beside that configuration. This lets purchasing compare equivalent proposals and makes a proposed substitution visible before production. Our construction-project procurement brief connects those requirements with the order and installation information.
Use a representative panel or machined detail to check supplied thickness, cut edges, openings and connection fit against the drawing. Record what that sample approves and retain its identity with the order and inspection records. The sample supports dimensional and workmanship acceptance; the designer's capacity checks and the applicable product evidence remain separate. Use the structural panel sample plan to agree that practical scope.
Keep material identity through receiving and changes
Match delivery marks, quantities and product documents to the agreed specification. Retain traceability when bundles are split or sheets are cut. Record damage or wetting at receiving before the material is mixed with other stock.
A substitution needs comparison of the relevant properties, construction and installation requirements. Matching sheet size and colour is insufficient. If a change affects the design assumptions, route it through the project's established technical decision process before incorporating the material.
Our defect-assessment guide explains why a visual finding needs to be connected to its location and intended load path.
Share the construction component you are planning
Send a floor, wall, roof or formwork drawing through our enquiry form. Tell us the panel sizes and quantity you have, together with the destination and any surface or machining needs. We can develop the supply quotation around the component you are building.
As the choice is settled, include the project designer's product standard, performance schedule and drawing revision. We connect those requirements to the proposed panel construction and supply documents; the project designer establishes the assembly design and connections.
Practical buying questions
Can I begin with a layout before the panel specification is complete?
Yes. Send the component drawing and the information you have. We can discuss panel construction and supplied dimensions while your project designer completes the grade, loading and connection requirements.
What does a structural panel sample help me check?
It helps compare supplied thickness, edge quality, machining and fixing fit with the drawing. Keep that sample approval alongside the project's product evidence and design assessment.