PLYWOOD & MDF · CHINA

STRUCTURAL PLYWOOD · FACTORY SUPPLY

Structural Plywood

Panels, cut parts and project records in one supply plan.

We manufacture structural plywood in our own factory in Jiangsu, China. Bring the floor, roof, wall or component you are planning; we will help develop the proposed panel construction, finished parts and supply around the project grade.

Start with your drawing, a site photo or the dimensions you have. We can work through the panel schedule with you, keeping the project requirements, product data, samples and labelled delivery connected for your purchasing and design teams.

Available to order · 10–15 day production · container shipping.

FULL SHEETS · CUT PARTS · PROJECT DELIVERY

Build the panel order around the work on site.

Bring your floor, roof, wall or component schedule. We’ll help bring the grade, panel construction, machining and labelled packs into one factory quotation, so your team can compare the supplied work and plan receiving.

Choose your panel format

Our technical sheet lists 1200 × 2400mm, 1220 × 2440mm and 1250 × 2500mm formats, with thickness options from 7 to 28mm. Send your cut list for finished parts or other dimensions.

Match the construction and edge

Select the pine/larch or eucalyptus core, face grade and square or tongue-and-groove edge with the required structural grade. Keep the selected thickness and direction with the installation drawing.

Receive the right parts together

Choose full sheets or machined components, with part identities and pack labels following your schedule. We can plan sample details, project documents and export packing around the order.

Available to order · production in 10–15 days · container shipping. Freight and delivery terms follow the order and destination.

TECHNICAL DATA · TDS-PS-17 · Rev 2.0 (Oct 2026)

Structural Plywood technical data

Structural plywood with pine or eucalyptus core, exterior phenolic bonding and square or tongue-and-groove edges. Compare the selected strength grade, thickness and sheet format with your project layout; the shipping table uses a 660 kg/m³ eucalyptus construction.

Open the complete technical data, properties and loading tables
Declared values from our technical data sheet TDS-PS-17, Rev 2.0 (Oct 2026). The values for your order are confirmed in the quotation.
Service Class / Exposure DutyService Class 2 & 3 Structural Load-Bearing Duty
Face / Back Veneer SpeciesStress-Graded Eucalyptus, Radiata Pine, Larch, or Birch (1.2–2.4 mm)
Surface Appearance GradeC/D (CDX Structural), C+/C (Sanded Face), or B/C (AS/NZS 2269 Grade)
Core Veneer Species100% Eucalyptus Hardwood (F14/F17 High-Strength) or 100% Coniferous Pine/Larch (F8/F11)
Edge Profile OptionsSquare Edge (SE) or Structural Tongue & Groove (T&G long edges for subflooring)
Adhesive SystemPhenolic Formaldehyde (WBP / EN 314-2 Class 3 / AS/NZS 2754.1 Type A Bond)
Standard Sheet Sizes1200 × 2400 mm (AU/NZ), 1220 × 2440 mm (UK/US), 1250 × 2500 mm (EU)
Length & Width Tolerance±1.0 mm (EN 315 / AS/NZS 2269)
Thickness Tolerance≤ 12 mm: ±0.3 mm | 15–28 mm: ±0.4 mm (EN 315)
Squareness≤ 1.0 mm / m (EN 324-2)
Edge Straightness≤ 1.0 mm / m (EN 324-2)
Harmonized System (HS) Code4412.33 / 4412.39
Reference StandardsEN 13986 (CE System 2+ / 4), EN 636-2 S / EN 636-3 S, EN 314-2 Class 3, AS/NZS 2269 (F11 / F14 / F17), PS 2
Physical and mechanical properties (declared values)
Density (Pine Structural / Eucalyptus Structural), kg/m³550–600 (Pine) / 650–720 (Eucalyptus)
Test method: EN 323
Moisture Content at Dispatch, %8.0 – 13.0
Test method: EN 322
Characteristic Bending Strength (fm,0 — Parallel), MPa≥ 42.0 (Pine) / ≥ 60.0 (Eucalyptus F17)
Test method: EN 310 / EN 789
Characteristic Bending Strength (fm,90 — Perp.), MPa≥ 28.0 (Pine) / ≥ 40.0 (Eucalyptus F17)
Test method: EN 310 / EN 789
Mean Modulus of Elasticity (Em,0 — Parallel), MPa≥ 10,500 (F11) / ≥ 12,000 (F14) / ≥ 14,000 (F17)
Test method: EN 310 / AS/NZS 2269
Mean Modulus of Elasticity (Em,90 — Perp.), MPa≥ 5,200 (F11) / ≥ 6,500 (F14/F17)
Test method: EN 310
Panel Shear Strength (fv), MPa≥ 4.5
Test method: EN 789
Bonding Quality (Type A / Class 3 Boil Test), MPa≥ 1.0 MPa / Bond Quality ≥ 6 (72h Boil)
Test method: EN 314-2 / AS/NZS 2098.2
Formaldehyde grade optionsE0 / E1; select the emission requirement with the order
Formaldehyde — chamber methodEN 717-1; chamber results are expressed in mg/m³
Formaldehyde — desiccator method, mg/L≤ 0.5 (Super E0 option with PF resin)
Test method: AS/NZS 4266.16

Weight and loading basis: nominal 1220 × 2440mm sheets at 660 kg/m³ for an eucalyptus-core configuration, before export packaging. Approximate 40HQ quantities use a 26.8-tonne panel allowance and rounded sheet weights. Pine-core, other sheet formats and the final pack arrangement have their own shipment weights and quantities.

Eucalyptus-core thickness, weight and estimated 40HQ loading · 660 kg/m³
Nominal Thickness Ply Count Area Weight Sheet Weight (1220 × 2440mm) Est. Load / 40HQ
7 mm7 plies4.62 kg/m²13.8 kg~1,942 pcs
9 mm7 plies5.94 kg/m²17.7 kg~1,514 pcs
12 mm9 plies7.92 kg/m²23.6 kg~1,135 pcs
15 mm11 plies9.90 kg/m²29.5 kg~908 pcs
17 mm13 plies11.22 kg/m²33.4 kg~802 pcs
18 mm13 plies11.88 kg/m²35.4 kg~757 pcs
19 mm13 plies12.54 kg/m²37.3 kg~718 pcs
21 mm15 plies13.86 kg/m²41.3 kg~648 pcs
25 mm17 plies16.50 kg/m²49.1 kg~545 pcs
28 mm19 plies18.48 kg/m²55.0 kg~487 pcs

Order options for Structural Plywood

Sizes, finishes & supply requirements

GIVE EVERY OFFER THE SAME BRIEF

Share the drawing or schedule you already have. We will help organise the required product standard, grade and approval route with the construction, dimensions and processing for the quotation. Identify alternatives separately so the project team can compare them clearly.

Information to include in a structural plywood enquiry
RequirementWhat to send
Project & structural roleDestination, permanent or temporary use, panel location, project specification and drawing revision.
Product standard & gradeNamed standard and edition, full structural grade/classification, required marking and project acceptance route.
Product & veneer identityRequired manufacturer/product reference, species, layup, face and reverse requirements, and permitted configuration changes.
Thickness & dimensionsSpecified thickness/category, finished dimensions, tolerances, edge profile and the stage at which they are measured.
Directional propertiesProperties required by the design, units, direction, thickness/configuration, statistical basis and applicable conditions.
Exposure & durabilityInstallation and service conditions, specified bonding/use classification, and separate treatment requirements if applicable.
Support & load caseProject-defined supports, clear spans or centre spacing, edge support, load type, location and design reference.
Connections & openingsPanel orientation, joint layout, fastener and fixing details, cut-outs, penetrations and their supporting details.
Required documentsApplicable declarations, grade evidence, product data, installation information and any sourcing or project requirements.
Sample & receiving checksSample purpose, dimensions and marking to inspect, approved reference, batch traceability and damage criteria.
Quantity & deliveryQuantities by configuration, destination, pack labels, handling constraints, receiving sequence and timing.

SEPARATE THE FOUR BUYING DECISIONS

Keep the structural grade and visible face clearly defined.

The structural role sets the required product classification and supporting information. We keep species, visible face, bonding and structural properties together in the offer as separate fields, making the proposed panel easier for your team to assess.

Read each part of the specification for its own purpose
DescriptionWhat it establishes
Wood & constructionSpecies and veneer arrangement identify the proposed panel build-up; they do not by themselves establish a structural rating.
Face appearancePermitted visible features and repairs on each side. A decorative face code is separate from structural classification.
Bond & exposureThe stated bonding/use classification and its conditions; these do not replace the required structural properties or biological durability evidence.
Structural classificationThe actual grade or declared properties under the relevant route, tied to the identified product, thickness and scope of use.
Uncoated plywood corner with natural veneer grain, an intact knot and two layered cut edges
Natural veneer face and adjoining layered plywood edges.

Describe the visible face and the specified construction together.

For exposed work, select permitted knots, repairs and the reverse-face range alongside the veneer schedule and structural classification. A face and cut-edge sample helps coordinate that appearance with the written product reference.

EN 636 covers both structural and non-structural plywood and different use conditions. Its name alone does not identify which classification applies to an offer. EN 13986 covers construction panels, their characteristics, conformity and marking; the actual intended use and applicable product documents still need to match.

Read the full designation on the actual product record.

In the EN 636 notation, the S designation identifies structural use and the 1, 2 or 3 classification concerns dry, humid or exterior use conditions. Keep the complete designation and edition with the proposed product; “EN 636 plywood” alone leaves both the structural-use and exposure question incomplete. SIS explains the structural-use notation.

For a North American panel brief, keep the applicable product standard, actual grade or performance rating, Performance Category and thickness information in their own fields. A Span Rating is not a thickness and its numbers are not free-standing installation instructions. APA explains how those fields appear on its trademarked panels; keep the proposed product’s own authorized marking and matching documents with your order.

A grade specified in one market is not an automatic equivalent of a differently named grade in another. Include the jurisdiction, standard edition and full requirement when asking about F17 or another structural designation. Keep any proposed substitution on a separate approval record.

MAKE THE DATA COMPARABLE

Bring the panel data your designer needs into the quotation.

Start with the properties your design team requires. Keep each property, direction, unit, test or derivation basis and condition tied to the proposed construction and thickness, so the data can be reviewed against the intended role.

Record both panel directions

Panel outline identifying perpendicular data directions D1 and D2D1D2
D1 / D2 · reference directions to identify in the actual product data.

Keep the comparison fields together

Product data record fields for identity, property, direction and basisProduct + thicknessProperty + unitsDirection + conditionsBasis + reference
Product, thickness, property, units and direction stay together in the data record.

Mark D1 and D2 from the selected product data on your drawing, cut list and part labels. Keep those directions with the required properties when reviewing the panel layout.

Open the guide to directional properties and data basis

Compare stiffness, strength and the relevant bending, tension, compression or shear properties on the same basis. Record whether each value is a test average, characteristic value or design value, with its direction and conditions. This helps your team compare the construction proposed by each supplier.

Compare like-for-like rows, not isolated headline numbers.

Connect each property to the product code, construction, finished thickness, direction, unit, condition and source document. Identify the modulus and basis for stiffness, and the relevant mode and statistical or design basis for strength.

Keep test results and the values used in the design in their own fields. The design team applies the relevant factors and limits for service, load duration and assembly, with the calculation retained alongside the selected product data.

EN 12369-2:2025 provides characteristic-value information with defined plywood construction limits. Keep the applicable plywood classification and construction scope with any standards-derived value for the project design team’s review.

APA’s plywood guidance distinguishes product standards, panel ratings and design information. Use the specified product standard and the proposed panel’s own grade and document references in the quotation.

CONNECT THE PANEL TO ITS POSITION

Order around the supports, joints and connections in your design.

Include the project-defined direction, supports, joints and connections with the panel schedule. These details let the design team assess the proposed construction in the arrangement where it will be used.

Floor or roof decking

Define the load case, panel direction, supports, joints and edge support. Record whether a dimension is a clear span or support centre spacing, and retain the drawing’s connection and service requirements.

Review support and connection fields

Wall sheathing or bracing

Identify the structural role and complete assembly. Panel properties alone do not establish the wall system’s resistance. Keep framing, fastening, joints, openings and load transfer with the design reference.

Distinguish panel roles

Other structural components

Show the component function, supports and connections with the required permanent structural classification. Include any formwork, marine-bonding or furniture requirement as its own part of the brief.

Review thickness, direction and supports

Make the support and joint detail easy to quote.

Mark support centre spacing and the clear distance between actual support faces on the drawing. Include panel direction, shared joints, edge support and openings. We can then quote the thickness, edge profile and processing against the same layout your design team is using.

Installation details to carry into the panel schedule
DetailInclude with your drawing
Supports and directionSupport positions and face widths, the clear-span datum, panel orientation and the applicable design reference.
Shared joints and edgesJoint positions, specified gaps, square or T&G; profiles, edge support and fixing locations.
Openings and machiningCut-outs, notches, penetrations, finished dimensions, tolerances and the drawing revision.
Use and exposureThe load case, service environment, installation wetting, drainage, ventilation and any specified treatment.

Have the project designer confirm the thickness, spans, joints and fixing schedule for the selected panel before production. We’ll carry that accepted layout through cutting, identification and packing, with any proposed change returned against the same drawing revision.

Plan protection for storage and installation as well as the finished use. Include the specified edge details, treatment and storage instructions with the panel schedule and delivery plan.

KEEP THE DIRECTION THROUGH CUTTING

Keep the required direction through cutting and delivery.

Mark the panel direction from the actual product data and project design on each component drawing and cutting list. We can carry that identity through part labels and packing after the original sheet marking is cut away.

Three separate rectangular plywood cut parts with natural veneer faces and layered sawn edges
Rectangular plywood cut parts with natural veneer faces.

Carry the panel reference into every cut part.

Connect each finished rectangle to its product, thickness, drawing revision and required data direction. Carry the reference through machining and packing, including when the original marking is cut away. Put the required direction on the cutting list and part labels so it stays clear at assembly.

Compare the same finished parts in each quotation.

Send part sizes and quantities with the required direction, permitted face features, actual edge trim and cutting allowance. Identify any rotation that the design team has accepted. We’ll use those requirements to plan full-sheet or cut-part supply, including spare parts and the finishing work your team needs.

From the cutting list to the delivered pack
Order itemWhat stays with the part
Finished dimensionsPart reference, length, width, thickness, edge profile, tolerance and machining drawing.
Direction and layoutMarked panel direction and any accepted rotation, with openings and joint positions.
Quantities and sparesRequired pieces by part and configuration, with spare parts listed separately.
Packing and identificationOrder line, product and grade reference, drawing revision, batch and receiving sequence.

Keep the selected panel, grade and thickness consistent across repeat parts. Record an accepted configuration change with its drawing and document revisions, then update the cutting list and pack labels together.

GIVE THE SAMPLE A DEFINED JOB

Review the selected panel and critical detail together.

We help plan a sample for product identification, face appearance, dimensions, machining or an installation-detail review. Keep the proposed product reference and applicable documents with it, giving purchasing and the design team a shared order reference.

A drawing, site photograph or current panel schedule is enough to begin. We’ll help choose the sample detail and retain its product reference as the order develops.

  1. 01

    Identify the proposal

    Record the manufacturer, product code, configuration, thickness and marking represented by the sample.

  2. 02

    Inspect the detail

    Review the agreed face features, dimensions, edges, handling and processing on the current drawing.

  3. 03

    Review the evidence

    Match grade and property information to the proposed product and the project’s acceptance requirements.

  4. 04

    Retain the reference

    Link the accepted sample, drawing revision and document list to the quotation and order.

Use the sample for the agreed dimensions, finish, edge and installation-detail checks. Keep the selected structural grade and property documents beside that reference. Where your project calls for additional testing, agree the construction, method and review requirements when planning the sample.

TIE THE APPROVAL TO THE OFFER

Bring the right product records into the project handover.

Send the project approval checklist when available. We will connect the document list with the proposed product, construction, thickness, intended use and destination, keeping issuer and relevant conditions clear for your project review.

Build the document pack around the selected structural grade, construction, thickness and destination. Include the applicable product declaration or grade record, marking and directional property data, then add the sourcing, emission, fire or treatment information your project requests.

Keep the same product and order references on the proposed supply, sample review, inspection and dispatch records. The selected configuration and intended-use scope make the pack useful to purchasing, design and receiving teams.

Review the construction-project document brief

Connect five records

  • Project specification, destination and drawing revision.
  • Actual producer, product code, grade, construction and thickness.
  • Applicable declaration, marking, property data and supporting evidence.
  • Accepted sample, inspection scope and approved changes.
  • Order, pack identification, production and delivery batch.
Discuss the required documents
Match project records to the structural panel order
RecordConfiguration to identify
Technical dataTDS-PS-17, selected core, grade, thickness, directions, property units and basis.
Project product documentsThe specified standard, intended-use scope, actual product reference, applicable marking and declaration or grade evidence.
Sample and machiningAccepted face, dimensions, edge detail, direction, processing and drawing revision.
Production and inspectionOrder line, selected construction, batch, dimensional and visual checks and approved changes.
Packing and dispatchPart or pack identity, quantities by configuration, protection, destination and delivery records.

PRESERVE THE REFERENCE AT RECEIVING

Receive the specified panels with their identity intact.

Plan panel, pack and paperwork identification with the order. Receiving checks can then connect marking, dimensions, visible condition and supplied documents to the selected configuration, including when packs are split or panels are cut.

Record any change to producer, veneers, layup, thickness, bond, treatment or marking as a proposed substitution. Keep it separate until the responsible project team accepts it. Similar appearance or the same nominal thickness is not sufficient to close that review.

We plan pack protection, support, lifting and storage information around the receiving conditions. Record any discrepancy against the order before installation and keep the product and document references with subsequent processing.

Make the delivered part identifiable after cutting.

Agree what information stays with a sheet, cut part and split pack: producer/product reference, grade or classification, thickness, required direction, order line and batch. Retain photographs of the authorized original marking with the relevant pack and documents. A cut part identifier is traceability, not a new grade stamp.

Count and inspect against each scheduled configuration separately. Keep dimensions, visible damage, edge processing, marking and document receipt in their own fields; a pack total cannot show whether the required directions and grades were supplied. Record held or replaced parts against the original order line so the accepted quantity remains clear.

Plan the order through delivery and after-sales support.

Available to order. Production takes 10–15 days, with timing recorded in the order confirmation. Panels ship by container; packing, freight and delivery terms follow the order and destination. Plan sea transit separately from production.

Supply includes a 180-day warranty. Contact our team with the order and pack references, photographs and details of any issue. We’ll agree the return or replacement solution and related freight for that order, keeping the selected configuration and project reference with replacement parts.

STRUCTURAL PLYWOOD BUYING QUESTIONS

Resolve the requirement before confirming the panel.

What makes plywood structural plywood?

Structural plywood is specified for load-bearing work using the selected product grade, construction and directional properties. We supply panels for floor, roof, wall and component schedules, with the grade, thickness, marking and required data connected to your project brief.

Is exterior-bonded or marine plywood automatically structural?

For a structural project, select the required structural grade alongside the exterior bond or marine requirement. Send both with the intended use and drawing so we can bring the construction, exposure conditions and matching product information into the quotation.

Does an F17 or CE name confirm the required grade?

Specify the required F17 grade or applicable CE documentation with the product standard, intended use and destination. We’ll identify the proposed construction and relevant product records for review. Keep face appearance and thickness as their own selections in the panel schedule.

Which thickness and span should we order?

Our technical sheet lists thickness options from 7 to 28mm. Send the project load case, supports, direction, edge support, connections and openings with the drawing. The project designer selects the thickness and span for that arrangement; we quote the selected panel and processing against the accepted schedule.

Can we compare suppliers using their bending-strength figures?

Compare only the relevant properties on a matching basis: product construction, thickness, direction, units, conditions and statistical or design basis. Stiffness, strength, typical averages, characteristic values and design values are not interchangeable.

Can the sheet be rotated to improve cutting yield?

Carry the required direction from the product data and project drawing into the cutting list. Include any rotation accepted by the design team, and we’ll use that approved layout when planning cut parts, quantities and pack identification.

What should a structural plywood sample prove?

Its agreed purpose, such as product identity, dimensions, appearance, machining or installation-detail fit. A representative sample helps purchasing compare the proposal, but structural acceptance still requires the applicable grade, performance and project design evidence.

Does PanelSource manufacture plywood?

Yes. We manufacture structural plywood in our own factory in Jiangsu, China. Share the structural role and destination, with your drawing or available dimensions. We will help develop the proposed construction and schedule, with applicable grade, marking, product data and documents identified for project review.

Is “EN 636” enough to define a structural order?

Include the full designation, edition and use condition with the identified structural product. Then add the thickness, construction, required directional data and project documents. Those fields let purchasing and the design team review the same panel proposal.

Should we quote clear span or support centre spacing?

Name the datum and include both dimensions where the drawing requires them. Clear span depends on actual support faces and their positions. Neither dimension alone selects the panel, joint or fixing for the design load.

How do we keep identity when the original panel stamp is cut away?

Agree sheet-to-part and pack records before machining. Carry the product, grade, thickness, direction and lot reference into the cut list and receiving records, with the original authorized marking and documents retained. A workshop label preserves identity; it does not certify a new grade.

What should we include in an enquiry?

Start with a drawing, site photo or the dimensions you have, plus approximate quantity and destination. Include the structural role, project grade or standard and document checklist when available; we will help complete the panel schedule and quotation scope.

Which sheet sizes and edge profiles can we order?

Our technical sheet lists 1200 × 2400mm, 1220 × 2440mm and 1250 × 2500mm formats, with square or tongue-and-groove edges. Send other dimensions or your cutting list with the required thickness, grade and direction for a full-sheet or finished-part quotation.

How long does production take and how are panels delivered?

Production takes 10–15 days according to the confirmed order. Panels ship by container, with freight and delivery terms agreed for your destination. Supply includes a 180-day warranty; returns or replacements and related freight are arranged for the order and issue.

MOVE FROM SCHEDULE TO A CLEAR OFFER

Bring your structural panel project to our factory team.

Send a drawing, site photo or existing dimensions, with quantity and destination if known. We will help complete the panel schedule, proposed construction, finished work and delivery scope. The project grade, design data and acceptance requirements stay with the responsible design team throughout that discussion.

Send us your panel requirements.

Tell us your panel, dimensions, quantity and destination port.

Request a quote ↗